JTREATTM is a leading water treatment company in Bangladesh. JTREATTM is the first ISO certified Bangladeshi water treatment company. We certified from Con Cert Quality Management(CCQM) GmbH, Switzerland.
We celebrate our achievement in our annual planning meeting. This meeting is very helpful and courageous for our team member. Every team member attended this annual meeting. Some honorable guests participated our program. The presence of Brig Gen Mirza Baker ( retd ),Ben Yamin, Raisul Islam(IBBL), Abdur Rahman Khan Rajon(CEO at BELIVER Compliance) in our ceremony gives us hope and pleasure. As a ccompany JTREATTM is focused, long visionary, user friendly. JTREATTM brand has his own R&D, BUET testing logo, experienced chemist. We manufacture chemical not import. This why JTREATTM assure cost savings and customized application for specific customers. JTREATTM now focus on export Bangladeshi water treatment chemicals.
Annual Business review and refreshment Training at
our Loyal Customer at Mongla, Khulna
At JTZ Engineering and Trading INN, we understand the importance of maintaining the proper chemical balance in cooling towers, boilers, RO systems, generators, and chillers. Our company provides a wide range of chemicals to ensure the smooth operation of these critical systems. Our team of experts has extensive knowledge and experience in water treatment, making us the trusted choice for many businesses.
Our focus is on providing high-quality, effective chemicals to improve the efficiency of your water treatment systems. Whether you need to reduce mineral buildup in boilers, prevent scaling in RO systems, or maintain optimal water balance in cooling towers, our JTREAT chemical can help.

Our products are designed to meet the needs of various industries, ensuring the right solution for your specific needs.
At JTZ Engineering and Trading INN, we believe that quality customer service is just as important as the quality of our products. Our team is dedicated to providing personalized support, helping you to select the right chemicals for your systems, and answering any questions you may have.
In conclusion, JTZ Engineering and Trading INN is your go-to source for performance and process chemicals for water treatment systems. We provide effective, reliable solutions that help you to maintain optimal performance, improve efficiency, and reduce downtime. Contact us today to learn more about our products and services
Chemical Treatment for cooling tower.
There are so many treatments process for cooling towers. Treatment for cooling towers can be both chemical and physical. Chemical treatment is a very easy and common treatment for the industry. So today we will try to learn about chemical treatment for cooling towers. Chemical treatment means using chemicals in the cooling towers to control corrosion, deposition, and microbiological growth.
Today we will learn about chemical treatment for corrosion control.
Corrosion Control (Inhibitors)
Corrosion is an electrochemical process in which metals are oxidized by transferring electrons from an anodic site to a cathodic site. Cathodic inhibitors reduce the amount of cathodic surface available and anodic inhibitors reduce the amount of anodic surface available. Sometimes both types of inhibitors are needed to prevent corrosion. Phosphates, zinc salts, and polyciliate are typical mild steel corrosion inhibitors, while organic nitrogen-based compounds (azoles) are copper alloy corrosion inhibitors.
Is JTREAT capable to control the corrosion of the cooling tower?
Yes, JTREAT Chemical has all kinds of inhibitions for controlling corrosion. For selecting chemicals, we
always find the actual problem of the industry. So, we visit the factory and collect all the cooling tower
information with makeup water, and blowdown water of the cooling tower. After collecting water, we
test the water in our lab and find the actual problem. Then we inform the responsible person in the
industry. After informing them we select our JTREAT chemicals such as JTREAT 1063, JTREAT 1132,
JTREAT 1181, JTREAT1316, JTREAT 1371, JTREAT 1709
Are you bleeding energy off your cooling tower for scaling and corrosion?
We are committed to save your asset and money, if it is related to Water. Common cooling water issues
Scale
Scale and scalelike deposits include calcium carbonate, calcium phosphate, magnesium silicate, silica and other mineral compounds They build up on heat exchanger tubes, reducing heat transfer In sufficient amounts they can restrict water flow When heat transfer is reduced, efficiency of production is reduced and the quality of products can be compromised Equipment can suffer damage from overheating Scale can cause expensive downtime for cleaning or repair, resulting in lost revenue. In addition, scale and scalelike deposits can accelerate corrosion.Our products JTREAT 7073/JTREAT 7032/JTREAT 7035/JTREAT 7024 will solve these Scale problem
Corrosion
Corrosion occurs when electrically charged particles flow through metal components, causing the metal to oxidize and eventually lose thickness Corrosion causes pitting and leaks in cooling systems and can lead to the replacement of pipes, pumps, heat exchanger tubes and even entire cooling towers oxide, especially, contributes to fouling and deposition, which interfere with heat transfer Downtime for equipment repair or replacement is always is always costly. Our products JTREAT9002/JTREAT 9181/JTREAT 9063/JTREAT 1063 will solve these corrosion problem
Organic fouling
Mud, sand, silt, clay, biological matter and even oil can enter the system through its makeup supply or from the air. These suspended materials can accumulate and settle in the system, blocking flow and reducing efficiency. Oil film can reduce heat transfer and encourage the growth of microorganisms. Our products JTREAT 8006/JTREAT 8007/JTREAT 1012 will solve these Organic fouling problem
Microbiological deposits
Biofilms severely restrict heat transfer. Slime masses bind inorganic and organic foulants and plug systems. Algae and fungi cause extensive plugging and fouling of heat exchanger tubes, water lines, tower spray nozzles, distribution pans, screens and fill. Microbiological fouling also contributes to under-deposit corrosion as well as the growth of corrosion-causing bacteria.Our products JTREAT 3847/JTREAT 6057/JTREAT 1057 solve these Microbiological deposits problem.
Foam
Cascading water, the continuous recycling of contaminants and a high concentration of foam stabilizers can cause foam to overflow the tower sump, blow off the towers or even cause an airlock in the water pumps. Worst of all, foam concentrates deposit-forming materials, increasing the chance of fouling in the system.Our products JTREAT 1034 will solve these foam problem
Why proper treatment is important
Because water is so good at dispersing minerals and helping living things grow, water in cooling systems must be specially treated and monitored. The goal is water that runs free
and clean, maximizing its ability to absorb heat and carry it away, so your systems stay cool.The key is water treatment optimization—the ability to not only apply the right chemistries but also to constantly monitor and control water quality to keep it balanced at all times. By monitoring pH, water temperature, electrical conductivity, microbiological activity,
corrosion, chemistry levels and other variables, your plant can be proactive. That not only helps keep contaminants from growing in your system but also helps you grow the bottom
line.
The right program can:
Increase production
Reduce downtime
Lower operating and chemical costs
Reduce your operation’s impact on the plane